Practical Sound Absorption Coefficient (αp)
Edge Thickness Suspension height 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz Sound absorption class αw NRC
AEX, A24 40mm 225mm 0.60 0.85 0.95 1.00 1.00 0.90 A 1.00 0.95
A24 20mm 200mm 0.50 0.95 1.00 0.90 1.00 0.95 A 1.00 0.95
A24 40mm 40mm 0.20 0.75 1.00 1.00 0.95 0.85 A 0.95 0.95

Sound absorption is measured in accordance with ISO 354.

Sound absorption data αp, αw and absorption class are calculated in accordance with ISO 11654. Sound absorption properties of islands and baffles are quantified by the equivalent sound absorption area Aeq expressed as m² per item.

Back
Sound curve
Back
Sound curve
Back
Sound curve

Other performances

Reaction To Fire Reaction To Fire A1 (EN 13501-1)
Reaction to fire is classified in accordance with EN 13501-1.
Fire Resistance Fire Resistance The fire resistant properties of stone wool ensure Rockfon ceiling tiles provide fire protection in construction. The fire protection properties of Rockfon ceilings have been tested and classified in accordance with European norm EN 13501-2 and/or national norms depending on requirements in national building codes.
The stone wool core of ROCKFON products is non-combustible with a melting point of more than 1000°C and provides fire protection. Some ROCKFON ceilings have been tested and classified in accordance with European norm EN 13501-2 and/or national norms.
Light reflection and light diffusion Light reflection and light diffusion 85%
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Humidity And Sag Resistance Humidity And Sag Resistance Up to 100% RH.
No visible deflection in high humidity
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Cleaning Cleaning Vacuum, Damp cloth
Vacuum: The surface can be vacuum cleaned with a soft brush attachment. Damp cloth: The surface can be cleaned using a damp cloth or sponge with a slightly alkaline detergent (pH between 7 and 9) without alcohol, ammonia or chlorine. This may render the surface slightly shinier, so we recommend cleaning the entire surface evenly.
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Environment Environment Fully recyclable stone wool
Indoor Environment Indoor Environment A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Impact Resistance Impact Resistance 20 mm : Class 3A (Rockfon System T24 A Impact 2A/3A)
40 mm : Class 1A (Rockfon System OlympiaPlus A Impact 1A)
40 mm : Class 2A (Rockfon System T24 A Impact 2A/3A)
Tested in accordance with EN13964-Annex D. Impact resistance classifications confirm the system´s capability to withstand incidental or occasional impact., EN 13964 annex D
Thermal Insulation Thermal Insulation Thermal conductivity:
λD = 37 mW/mK (40mm)
The thermal conductivity of products with a thickness ≥ 30mm is measured in accordance with EN 12667 and expressed in mW/mK. Thermal resistance is expressed in m²K/W.
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
The stone wool core of ROCKFON products is non-combustible with a melting point of more than 1000°C and provides fire protection. Some ROCKFON ceilings have been tested and classified in accordance with European norm EN 13501-2 and/or national norms.
Back
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Back
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Back
Vacuum: The surface can be vacuum cleaned with a soft brush attachment. Damp cloth: The surface can be cleaned using a damp cloth or sponge with a slightly alkaline detergent (pH between 7 and 9) without alcohol, ammonia or chlorine. This may render the surface slightly shinier, so we recommend cleaning the entire surface evenly.
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Back
Back
Back
Back
The thermal conductivity of products with a thickness ≥ 30mm is measured in accordance with EN 12667 and expressed in mW/mK. Thermal resistance is expressed in m²K/W.
Back

Full range

Edge Dimensions (mm) Thickness (mm) Weight (Kg/m2) Min. suspension height (mm) Recommended installation system  
A24 1200 x 600 20 2.40 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 12
Area Per Pack 8.64 m2
A24 1200 x 600 40 4.10 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 10
Area Per Pack 7.20 m2
A24 1800 x 600 20 2.40 50 Rockfon® System T24 A

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 12
Area Per Pack 12.96 m2
A24 1800 x 600 40 4.10 50 Rockfon® System T24 A

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 10
Area Per Pack 10.80 m2
A24 2100 x 600 20 2.40 50 Rockfon® System T24 A

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 12
Area Per Pack 15.12 m2
A24 2400 x 600 20 2.40 50 Rockfon® System T24 A

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 12
Area Per Pack 17.28 m2
A24 2400 x 600 40 4.10 50 Rockfon® System T24 A

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 10
Area Per Pack 14.40 m2
A24 600 x 600 20 2.40 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 24
Area Per Pack 8.64 m2
A24 600 x 600 40 4.10 50

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 50 mm

Packaging

Pieces Per Pack 20
Area Per Pack 7.20 m2
AEX 1166 x 1166 40 4.10 180 Rockfon® System Olympia Plus A Impact 1A

Recommended installation system

Impact resistance Rockfon® System Olympia Plus A Impact 1A Ideal combination of good acoustics and impact resistance for sports halls

Sound absorption details

αw 1.00
NRC 0.95
Sound absorption class A

Tile details

Minimum installation height 180 mm

Packaging

Pieces Per Pack 5
Area Per Pack 6.80 m2

MS = Minimum Suspension

Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 12
Area Per Pack 8.64 m2
Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 10
Area Per Pack 7.2 m2
Back

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 12
Area Per Pack 12.96 m2
Back

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 10
Area Per Pack 10.8 m2
Back

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 12
Area Per Pack 15.12 m2
Back

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 12
Area Per Pack 17.28 m2
Back

Recommended installation system

Visible grid ceiling system Rockfon® System T24 A Ceiling system with a 24 mm wide visible grid with A edge tiles

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 10
Area Per Pack 14.4 m2
Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 24
Area Per Pack 8.64 m2
Back

Sound absorption details

Tile details

Minimum installation height 50 mm
Easy access -

Packaging

Pieces Per Pack 20
Area Per Pack 7.2 m2
Back

Recommended installation system

Impact resistance Rockfon® System Olympia Plus A Impact 1A Ideal combination of good acoustics and impact resistance for sports halls

Sound absorption details

Tile details

Minimum installation height 180 mm
Easy access -

Packaging

Pieces Per Pack 5
Area Per Pack 6.8 m2
Back

Downloads

documents

 

 

pdf dwg
Rockfon® Boxer | Datasheet
Rockfon® Boxer | Datasheet

pdf
Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD)

pdf
Rockfon® System Olympia Plus A Impact 1A | Installation Guide
Rockfon® System Olympia Plus A Impact 1A | Installation Guide

pdf
Rockfon® System T24 A | Installation Guide
Rockfon® System T24 A | Installation Guide

pdf
pdf
pdf
pdf
pdf
A-edge - angle-trim-vertical-bulkhead | CAD
A-edge - angle-trim-vertical-bulkhead | CAD

pdf
dwg
A-edge special column ring - flexible perimeter trim | CAD
A-edge special column ring - flexible perimeter trim | CAD

dwg
pdf
A-edge - gypsum level shift - 90 degree | CAD
A-edge - gypsum level shift - 90 degree | CAD

pdf
dwg
A-edge - 10mm space between tile and column | CAD
A-edge - 10mm space between tile and column | CAD

dwg
pdf
A-edge - angle trim - 90 degree | CAD
A-edge - angle trim - 90 degree | CAD

pdf
dwg
E+A-edge - concrete TT beams | CAD
E+A-edge - concrete TT beams | CAD

pdf
dwg
DoP-RFN-0005-041-4 - Rockfon® Boxer
DoP-RFN-0005-041-4 - Rockfon® Boxer

pdf
Back